INSPECTION PITS

INTRODUCTION

Kingsmill Concrete Inspection Pits are suitable for load rating to 4,500kg and are suitable for most types of Earthing and Lightning Protection installations.

The Plastic Inspection Pit protects the Earth Rod connection and makes it available for inspection. The Plastic Inspection Pit can have up to 3 Earth Bars fitted in the slots provided for multiple connections.

Concrete Inspection Pit

CONCRETE INSPECTION PITS

Concrete Inspection Pits are suitable for load rating to 4,500kg and are suitable for most types of Earthing and Lightning Protection installations.

Concrete Inspection PitConcrete Inspection Pit b

Concrete Inspection Pit

Concrete Inspection Pits are suitable for load rating to 4,500kg and are suitable for most types of Earthing and Lightning Protection installations.

Material:

Concrete

Standard:

BS:EN 62561-5:2011

The Concrete Inspection Pit protects the Earth Rod connection and makes it available for inspection. The Concrete Inspection Pit can have an Earth Bar fitted diagonally in slots provided for multiple conductor connections.

Inspection Pit Earth Bars for Concrete Inspection PitInspection Pit Earth Bars for Concrete Inspection Pit b

Inspection Pit Earth Bars (for Concrete Inspection Pit)

Inspection Pit Earth Bars are used to facilitate testing of the earth electrode or earthing system.

Material:

Copper/Tinned Copper

Standard:

BS:EN 13601

The Earth Bar can be fitted into slots, to provide for multiple conductor connections.

To request a quotation, select the version you require using the drop down options below.

Lightweight Concrete Inspection Pits are suitable for load rating to 4,500kg and are suitable for most types of Earthing and Lightning Protection installations.

Concrete Inspection PitConcrete Inspection Pit b

Lightweight Concrete Inspection Pit

Lightweight Concrete Inspection Pits are suitable for load rating to 4,500kg and are suitable for most types of Earthing and Lightning Protection installations.

Material:

Concrete

Standard:

BS:EN 62561-8:2011

The Lightweight Concrete Inspection Pit protects the Earth Rod connection and makes it available for inspection. The Inspection Pit can have an Earth Bar fitted diagonally in slots provided. These Earth Bars allow for multiple conductor connections.

Concrete Inspection Pits – 500 x 500 are designed for use where more space is required in the chamber.

Inspection Pit Earth Bars for Concrete Inspection Pit

Inspection Pit Earth Bars (for 500 x 500 Concrete Inspection Pit)

Inspection Pit Earth Bars are used to facilitate testing of the earth electrode or earthing system.

Material:

Copper/Tinned Copper

Standard:

BS:EN 13601

Inspection Pit Earth Bars can be fitted diagonally in slots provided in the Concrete Inspection Pit. These allow for multiple conductor connections.

To request a quotation, select the version you require using the drop down options below.

Enhanced Concrete Inspection Pits with lifting eye/brass plate can be customised to your exact requirements.

Concrete Inspection Pits with lifting eye brass plate bConcrete Inspection Pits with lifting eye brass plate

Concrete Inspection Pits (with lifting eye/brass plate)

Enhanced Concrete Inspection Pits with lifting eye/brass plate can be customised to your exact requirements. The lifting eye makes it easy to remove the pit lid for applications where regular inspection is required.

Material:

Concrete

Inlaid brass plates can be engraved as required. Typical engraving includes identification and safety notices and these can be produced in any language.

To request a quotation, select the version you require using the drop down options below.

Inspection Pit Earth Bars for Concrete Inspection PitInspection Pit Earth Bars for Concrete Inspection Pit b

Inspection Pit Earth Bars (for Concrete Inspection Pit)

Inspection Pit Earth Bars are used to facilitate testing of the earth electrode or earthing system.

Material:

Copper/Tinned Copper

Standard:

BS:EN 13601

The Earth Bar can be fitted into slots, to provide for multiple conductor connections.

To request a quotation, select the version you require using the drop down options below.

PLASTIC INSPECTION PITS

PLASTIC INSPECTION PITS protect the Earth Rod connection and make them available for inspection. The Plastic Inspection Pit can have up to 3 Earth Bars fitted in the slots provided for multiple connections.

Plastic Inspection Pit

Plastic Inspection Pit

The Plastic Inspection Pit protects the Earth Rod connection and makes it available for inspection. The Plastic Inspection Pit can have up to 3 Earth Bars fitted in the slots provided for multiple connections.

Material:

Polypropylene (body), GRP (lid)

Standard:

BS:EN 62561-5:2011

Paving can be laid up to the lid edge without an unsightly concrete filler surround. Installation instructions are printed on the side. Will withstand 6000kg load when installed correctly. Lockable lid, using a screwdriver or special key to release the locking mechanism.
Plastic Inspection Pit dimPlastic Inspection Pit b

Inspection Pit Earth Bars for Concrete Inspection PitEarth Bars for Plastic Inspection Pit

Earth Bars (for Plastic Inspection Pit)

Inspection Pit Earth Bars are used to facilitate testing of the earth electrode or earthing system.

Material:

Copper

Standard:

BS:EN 13601

The Inspection Pit Earth Bar can be fitted width ways in slots provided in the base of the Plastic Inspection Pit (three slots per pit).

To request a quotation, select the version you require using the drop down options below.

LIGHT DUTY PLASTIC INSPECTION PITS are suitable for load rating to 500kg and are suitable for most types of Earthing and Lightning Protection installations.

Light Duty Plastic Inspection Pit

Light Duty Plastic Inspection Pit

Light Duty Plastic Inspection Pits are suitable for load rating to 500kg and is suitable for most types of Earthing and Lightning Protection installations.

Material:

Polypropylene

Standard:

BS:EN 62561-5:2011

The Light Duty Plastic Inspection Pit protects the Earth Rod connection and makes it available for inspection. The pit can have an Earth Bar fitted width ways in slots provided for multiple connections.

Light Duty Plastic Inspection Pit dim

Inspection Pit Earth Bars for Concrete Inspection PitEarth Bars for Light Duty Plastic Inspection Pit

Earth Bars (for Light Duty Plastic Inspection Pit)

Inspection Pit Earth Bars are used to facilitate testing of the earth electrode or earthing system.

Material:

Copper

Standard:

BS:EN 13601

The Earth Bar can be fitted width ways in a slot (one) provided. The Earth Bar allows for multiple conductor connections.

To request a quotation, select the version you require using the drop down options below.